Filament Wound Pressure Pipe

 

Below is a typical cross section of Filament Wound Part.
ASTM Formula for calculating the filament wound pipe side wall thickness:

Thickness in inches at dimension E
D = Diameter in inches
H = Head height in inches based on dimension E
SG = Specific Gravity of liquid (pounds/cubic foot)

This ASTM formula includes a 10:1 safety factor. Please note that a correctly designed tank does not include the corrosion barrier thickness in the calculation of the wall thickness.



  • Vacuum ratings are based on a 5 to 1 safety factor for unstiffened pipe.
  • Ratings are suitable for operating temperatures to 180°F (82°C) with premium resins.
  • Pressure ratings are based on the specified strain for each "grade".
  • Standard pressure classes are shown. Custom designs can be provided for specific requirements.


    Grade A
    - Premium grade pipe that includes a 200 mil structural liner and a strain limit of .0012 in./in.

    Grade B - Standard grade pipe that includes a 100 mil structural liner and a strain limit of .0014 in./in.

    Grade C - Commercial grade pipe that includes a 50 mil structural liner and a strain limit of .0017 in./in.

  •  